product_img

RBmax5.1

Developed with cobalt free lithium ferro-phosphate (LFP) cells, embedded BMS (battery management system) to provide utmost safety, high reliability, and longer service life.

Product Description

Product Specifications

PDF Download

maidian
maidian

Sleek. Compact. Exquisite

Modular Design
Easily expandable by stacking modules

  • 5.1

    kWh

    Starting
    Capacity (1 module)

  • 40.8

    kWh

    Maximum Capacity

maidian
maidian

Safe LiFePO4 Chemistry

Premium electrical characteristics
No need to suffer from safety issues
maidian

ESS SOLUTION

Reduce reliance on grid electricity
Save more on energy bills
maidian maidian
maidian

Built-in BMS

Intelligent monitoring & management of battery status

Comprehensive protections

such as:
  • Over temperature cutoff
  • Over voltage cutoff
  • Short circuit protection
  • Over charge / discharge cutoff
  • Over current cutoff
maidian

Utilize Free & Clean Solar Energy
As Much As Possible

maidian
  • Morning

    Minimal solar generation, high demand.

  • Midday

    Maximum solar generation, low demand.

  • Evening

    Minimal solar generation, highest demand.

Electric Data

  • Nominal Energy (kWh)

    5.1 kWh
  • Usable Energy (kWh) [1]

    4.74 kWh
  • Cell Type

    LFP (LiFePO4)
  • Nominal Voltage (V)

    51.2
  • Operating Voltage Range (V)

    44.8 ~ 56.8
  • Max. Continuous Charge Current (A)

    50
  • Max. Continuous Discharge Current (A)

    100

General Data

  • Weight (Kg)

    50
  • Dimensions (W * D * H) (mm)

    650 * 240 * 475
  • Operating Temperature (℃)

    0℃ ~ 55℃ (Charge); -20℃ ~ 55℃ (Discharge)
  • Storage Temperature (℃)

    -20℃ ~ 55℃
  • Relative Humidity

    0℃ ~ 95℃
  • Max. Altitude (m)

    4000 (> 2000m derating)
  • Protection Degree

    IP65
  • Installation Location

    Ground-mounted; Wall-mounted
  • Communication

    CAN, RS485

Certifications

  • Safety

    IEC 62619, UL 1973
  • EMC

    CE
  • Transportation

    UN 38.3

Warranty (Years) [4]

  • Warranty (Years)

    5 / 10 (Optional)
[1]

Test method: Under STC condition, discharge to 2.5 V with a constant current of 0.5 c, rest 30 minutes; charge to 3.65 V with a constant current of 0.5 c, rest 5 minutes, then charge to 3.65 V with a constant current of 0.05 c and rest 30 minutes. Discharge with a constant current of 0.5 c till the voltage is 2.5 V.

[2]

Optional high-performance version, supporting the maximum continuous current of 200A application conditions

[3]

Test method: Under STC conditions, run 1 cycle per day.

  • File Name
  • File Type
  • Language
  • pdf_ico

    ROYPOW SUN S Series

  • Inverter + RBmax5.1L Leaflet
  • EN
  • down_ico
  • sns-11
  • sns-21
  • sns-31
  • sns-41
  • sns-51

Subscribe to our newsletter

Get the latest ROYPOW's progress, insights and activities on renewable energy solutions.