Hybrid inverter - US provides a perfect solution for PV and battery energy management. The featured high DC to AC energy efficiency guarantees low conversion loss and effectively reduces energy wastes and ensures optimal system operation.
Convenient to set up parameters through LCD panel easily
Easy-accessible button operation
Full visibility & Remote operation
Check the running status at anytime
Optimize storage settings from anywhere
Support multi-parallel connection
Support flexible access of generator
Minimal solar generation, high demand.
Maximum solar generation, low demand.
Minimal solar generation, highest demand.
Max. Input Power (W)
12000Max. Input Voltage (V)
500MPPT Voltage Range (V)
125 - 500Start Operation Voltage (V)
120Max. Input Current (A)
12 + 12 + 12 + 12Max. Short Current (A)
15 + 15 + 15 + 15No. of MPPT
4No. of String per MPPT
1DC Switch
IntegratedBattery Type
LFP (Integrated BMS)Nominal Voltage (V)
48Operation Voltage Range (V)
40 - 58Max. Charge / Discharge Power (W)
8000 / 8000Max. Charge / Discharge Current (A)
190 / 190Battery Charge Method
Self-adaption to BMSNominal Apparent Power (VA)
8000Max. Apparent Power (VA)
8800Max. Active Power (W)
8000Max. Input Power (VA)
12000Grid Type
L1, L2, N, PENominal Frequence (Hz)
50 / 60Grid Voltage Range (V)
102 - 132 / 204 - 264Nominal Voltage (V)
120 / 240 (Split Phase)Frequence Range (Hz)
45 - 55 / 55 - 65Max. Output Current (A)
38.3Max. Input Current (A)
50THDI (Rated power)
< 3%PF
- 0.8 ~ + 0.8Switch Time
10 ms (Typical)Max. Active Power (W)
8000Nominal Frequence (Hz)
50 / 60Frequence Accuracy (Hz)
± 0.1Nominal Voltage
120 / 240 (split phase)Max. Output Current (A)
38.3Voltage Accuracy
± 1%THDV (100%R Load)
< 2%Output Parellel (Pcs)
6Over Load
105% < Load ≤ 125%, 1 min; 125% < Load ≤ 150%, 1SOutput Parallel (Pcs)
3Max. Efficiency
98.2%North American Efficiency
≥ 97.2%GFCI
√Anti-islanding Protection
√PV String Input Reverse Polarity Protection
√Output Over Voltage Protection
√Output Over Current Protection
√Output Short Protection
√Insulation Resistance Detection
√DC / AC Surge Protection
Type 3Dimension (W * D * H) (mm)
430 *220 * 710Net Weight (kg)
41Operating Temperature Range
-25 ~ 60℃ (45℃ derating)Relative Humidity
0 ~ 95% (non-condensing)Max. Altitude (m)
4000 (> 2000m derating)Electronics Protection Degree
IP65 / NEMA 3RTopology Type
Transformerless, Isolation (Bat to AC)Night Self Consumption (W)
< 3Cooling
Smart FANNoise (dB)
< 29HMI
APP / LCDCOM
RS485 / CAN / WiFi / 4G (Optional)Safety
UL 1741SA, UL 1699B, CSA 22.2EMC
FCC Part 15 ClassGrid Code
IEEE 1547, IEEE 2030.5Warranty (Years)
5 / 10 (Optional)